This innovative single quadrupole (SQ) ICP-MS is the ideal trace elemental analyzer for a wide range of sample types and industries; from 24/7 routine analysis to advanced applications in research.
Confidently measure trace and major analytes in some of the most challenging matrices. Optimize productivity and accuracy with comprehensive interference removal for reliable multi-elemental analysis. Whether analyzing drinking water, waste water or soil digests, the high-throughput, iCAP RQ ICP-MS meets demanding environmental requirements, such as US EPA 200.8 with ease.
Model: RA-915 M
RA915M Mercury Analyzer with NEW Pyrolyzer PYRO-915+ is a portable multifunctional atomic absorption spectrometer with Zeeman background correction, which eliminates the effect of interfering impurities. It is the only high sensitivity and selectivity instrument that does not require gold amalgam pre-concentration and subsequent regeneration steps. This enables the user to conduct real time air monitoring and detection of a mercury vapor. Being combined with pyrolysis or cold vapour attachments for liquid and solid sample testing, the instrument can determine mercury content in water, soil, food prodcuts, natural and stack gases, may be used for dental and toxicological applications, etc. RA-915M Mercury Analyzer with new pyrolyzer PYRO-915+ (with large optical length of analytical cell and heated windows of the analytical cell is developed for unique direct mercury determination (no pretreatment procedures required) in complex organic samples at the level of ppb and even sub ppt levels (depending on environmental conditions and attachments used).
Model: Multiwave PRO (Anton Paar)
The Multiwave PRO microwave reaction system delivers the sample preparation solutions you need to obtain excellent trace analysis results. Multiwave PRO masters high temperatures and provides comprehensive reaction control features. Its wide range of accessories allows digestion, leaching, oxygen combustion, solvent extraction, drying, evaporation, and UV digestion with one single system.
Multiwave PROhas two magnetrons of 850 W each to ensure a consistent delivery of 1500 W over its lifetime. Unpulsed microwave power over the whole range ensures precise control of critical reactions.
Microwave digestion usually takes place in closed vessels under pressures up to 2000 psi. Open vessel digestion methods can reach pressures of over 2500 psi at up to 300 °C.
Model: XRF Axios Max (PANalytical). Equiped with standardless analysis software (Omnian).
XRF is an analytical method to determine the chemical composition of all kinds of materials. The materials can be in solid, liquid, powder, filtered or other form. XRF can also sometimes be used to determine the thickness and composition of layers and coatings. The method is fast, accurate and non-destructive, and usually requires only a minimum of sample preparation. Applications are very broad and include the metal, cement, oil, polymer, plastic and food industries, along with mining, mineralogy and geology, and environmental analysis of water and waste materials.
Features:
- Simultaneous measurement of up to 28 elements, with a minimum of 2 second measurement per sample
- High sensitivity HiPer channels for light-element analysis
- Analytical flexibility with the option of up to 4 goniometers
- Range of X-ray anode materials (Rh, Cr, Mo, Au) enables highest performance for specific application
Model: STA 6000 (Perkin Elmer). It combines DSC and TGA thermal techniques
The STA 6000 simultaneous thermal analyzer offers performance, reliability and productivity you can depend on. Designed with routine and research applications in mind, the STA 6000 simultaneous thermal analyzer applies advanced innovative sensor technology to yield higher accuracy and quality results.
The patent pending SaTurnA™ sensor and proven compact furnace allows for better temperature control, more consistent measurements and the fastest cool-down time. Operation is from 15 °C to 1000 °C
Features
- Simultaneous analysis of TG with DTA mode (∆T) and DSC (mW) mode for fast enhanced result interpretation
- Innovative patent pending SaTurnA sensor to measure both sample and reference temperature directly for superb performance
- Vertical displacement balance sensor (not rotational) provides weight insensitivity to sample position, e.g., no spurious weight change from melting
Model: Agilent 1260 Infinity Quaternary. Equiped with autosampler, Diode Array Detector and automatic switch between four different columns.
High performance liquid chromatography is a step up from column chromatography. It involves the solvent being forced through a column at high pressures to achieve separation in a laboratory setting in less time than traditional methods. HPLC results in better separations, increased accuracy, and sensitivity through a more automated process.
The Agilent 1260 Infinity Quaternary LC is ideally suited for multi-method, high-throughput workflows. It offers:
• Convenient access to four solvents for isocratic or gradient analysis for rapid method development and speed up preparation of mobile phases and flushing the HPLC system.
• Pressure range up to 1200 bar.
• A wide flow range up to 10 mL/min and a delay volume of 800 – 1100 µL supports narrow-bore, standard and semi-preparative applications.
• Easy programming and control through the Instant Pilot G4208A (requires firmware B.02.08 or above) (p/n G4208-67001) or through an Agilent Data System.
• Included micro vacuum degasser offers high degassing efficiency for trouble-free operation and highest performance and completely eliminates the need for helium sparging.
Model: Du Master D-480 (Buchi). Equiped with autosampler suitable for both liquid and solid samples.
The DuMaster D-480 enables unattended and flexible determination of nitrogen or protein according to the Dumas combustion method. The short analysis time of approximately 4 minutes per sample, coupled with the built-in autosampler accommodating up to 120 samples, makes this instrument perfectly suitable for high throughput without supervision.
Model: Mastersizer 3000 (Malvern). Equiped with both Hydro and Aero modules for wet and dry analysis, respectivelly.
The Mastersizer 3000 measures particle size using the proven technique of laser diffraction. A particle size distribution is calculated from measurements of the angular intensity of scattered light produced by a sample. The optics required to capture this data lie at the heart of the system. In a new, folded optical design, a blue solid state light source in the Mastersizer 3000 provides resolution in the sub-micron range, resolving materials down to 10nm in size. A rapid data acquisition rate significantly increases the amount of measurement data feeding into the analysis. Analytical reproducibility is improved, and even the most polydisperse samples are characterized accurately.
Model: Autosorb iQ (Quantachrome)
A highly sophisticated gas sorption analyzer available with up to three physisorption analysis ports for surface area analysis and pore size measurements, two of which can be equipped for low pressure micropore analysis including optional 0.1 torr transducer(s).